SYSTOC HL7 Exchange Communication Requirements
Implementation of the SYSTOC HL7 Exchange modules requires the participation and commitment of three groups: Workplace Health & Safety (WHS), the WHS customer, and the staff from the third-party system (laboratories, radiology facilities, or hospital information systems). Customers provide project leadership and resources that work with WHS engineering staff and third-party system staff to maintain progress and see the project to completion. WHS staff can only implement these interfaces with committed customer and third-party resources.
SYSTOC HL7 Exchange Module | HL7 Version | Specific HL7 message requirements | |
---|---|---|---|
HL7 Clinical Laboratory Interface | |||
Outbound orders (SYSTOC to laboratory) | 2.5.1 or 2.6 | accept OML_021 in MSH-9 | |
Inbound orders (Laboratory to SYSTOC) | return identifying information in OML_021 in MSH-9 and return using OML_021 in MSH-9 | ||
HL7 Drug Testing Interface | |||
Outbound orders (SYSTOC to drug test laboratory) | 2.5.1 or 2.6 | accept OML_021 in MSH-9 | |
Inbound orders (Drug test laboratory to SYSTOC) | return Requisition ID from the original sample using OML_021 in MSH-9 | ||
Note: Laboratories sending both clinical laboratory and drug test results must
distinguish between those two types of results using a method acceptable to
Workplace Health & Safety.
|
|||
HL7 Radiology Interface | |||
Outbound orders (SYSTOC to radiology unit) | 2.5.1 or 2.6 | accept OML_023 in MSH-9 | |
Inbound orders (Radiology unit to SYSTOC) | return identifying information in OML_023 in MSH-9 and
return using ORU_R24 in MSH-9 Report file attachments must use Base64 encoding and be sent using HL7 messaging |
||
HL7 Patient ADT Interface | |||
Inbound (to SYSTOC) | 2.3, 2.5.1, or 2.6 | ADT_A04 or ADT_A08 | |
HL7 Document Interface* | |||
Outbound (from SYSTOC) | 2.5.1 or 2.6 | accept ORU_R01 in MSH-9 | |
HL7 Continuity of Care Record (CCR)* | |||
Outbound (from SYSTOC) | 3.0 | accept XML syntax |
* The HL7 Document Interface and Continuity of Care Record Interface require Workplace Health & Safety implementation and custom development services for a single trading partner for each interface.